| Laitance |
A weak layer of cement and aggregate fines on a concrete surface that is usually caused by an over-wet mixture, overworking the mixture, improper or excessive finishing, or combination thereof. |
| Laminate |
To join layers of materials together using fusion; the process of joining layers of materials together using adhesion. |
| Laminated shingles |
See "dimensional shingle." |
| Lap |
That part of a roofing, waterproofing or flashing component that overlaps or covers any portion of the same or another type of adjacent component. |
| Lap cement |
An asphalt-based roof cement formulated to adhere overlapping plies or asphalt roll roofing. |
| Lap seam |
Occurs where overlapping materials are seamed, sealed or otherwise bonded. |
| Launderability |
The ability of a reflective coating to resist dirt pickup and the ease with which it can be cleaned, especially by natural means such as ordinary rain events. |
| Leaching |
(1) The action of removing soluble constituents from a solid into a solution; (2) the dissolving out of soluble substances when water seeps through a roof system. |
| Lead |
A soft, malleable, naturally weathering heavy metal; has low melting point and a high coefficient of thermal expansion. |
| Leeward |
The direction opposite that from which the wind is blowing. The side sheltered from the wind. For comparison, see "windward." |
| Life-cycle assessment (LCA) |
A method of evaluating a product or system by reviewing the ecological effect over its entire life. Life stages include extraction of raw materials, processing and fabrication, transportation, installation, use and maintenance, and reuse, recycling and disposal. At each stage, the product or system and its components are evaluated based on materials and energy consumed and the pollution and waste produced. LCA is an environmental review methodology. |
| Life-cycle cost analysis |
A technique of economic evaluation that sums up the costs of a product or system during its entire life, including raw materials extraction, processing and fabrication, transportation, installation, use and maintenance, and reuse, recycling or disposal. At each stage the product or system and its components are evaluated based on the costs of materials and energy consumed and pollution and waste produced. |
| Lift |
The spray polyurethane foam that results from a pass. It usually is associated with a certain pass thickness and has a bottom layer, center mass and top skin in its makeup. |
| Lightweight aggregate |
See "aggregate, lightweight." |
| Lightweight or insulating concrete fill (LWIC) |
Concrete made with or without aggregate additions to Portland cement, water and air to form a hardened material that, when oven-dried, will have a unit weight of 50 lb/ft3 or less. |
| Liquid-applied |
Application of bituminous, polymer-modified bitumen or polymeric roof and waterproofing membranes, flashings, cements, adhesives or coatings installed at ambient or slightly elevated temperatures. |
| Liquid-applied built-up roof |
A continuous, semi-flexible roof membrane consisting of multiple plies of felts, mats or fabrics laminated together with alternate layers of roof cements and surfaced with a liquid-applied coating with or without aggregate surfacing. |
| Liquid-applied roof membrane |
A continuous roof membrane constructed in place with a liquid resin and reinforcing material. The liquid resin is available as a one- or two-component product and typically is applied in two coats. Depending on resin chemistry, a catalyst or hardener may be added to induce the curing process. The reinforcement typically is polyester or fiberglass mat set into the resin base coat. |
| Live loads |
Temporary loads that the roof structure must be designed to support, as required by governing building codes. Live loads are generally moving and/or dynamic or environmental (e.g., people, installation equipment, snow, ice, rain). |
| Long-term thermal resistance (LTTR) |
A method for determining and reporting estimated long-term R-values of unfaced or permeably faced rigid gas-filled closed-cell plastic foam insulations by reducing the specimen thickness to accelerate aging under controlled conditions. This method is reported to account for the diffusion of the blowing agent from the foam insulation’s cells over time, resulting in a recognized reduction of thermal resistance of some plastic foam insulations as they age. The R-values produced by the LTTR method correspond to the thermal resistances measured for insulation materials stored in controlled laboratory conditions until they have aged five years. LTTR values are reported for polyisocyanurate rigid board insulation in accordance with ASTM C1289, “Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board.” |
| Loose-laid membrane |
Ballasted membrane that is attached to the substrate only at the edges and penetrations. |
| Lot |
In roofing: (1) production lotall material produced in one eight-hour shift of the same type (and color when applicable); (2) delivery lotall material of the same type delivered at one time by one truck or railroad car. |
| Low-slope roofs |
A category of roofs that generally includes weatherproof membrane types of roof systems installed on slopes at or less than 3:12. |
| Low-temperature flexibility |
The ability of a membrane or other material to resist cracking when flexed after it has been cooled to a low temperature. |