The Roofing Industry Committee on Weather Issues Inc. has investigated hundreds of metal panel roof system failures resulting from high-wind events, including Hurricanes Charley, Ivan, Katrina, Ike and Irma. In every RICOWI report, metal flashing failures are cited as a cause of metal panel roof system failures. A new standard, ANSI/MCA FTS-1-2019, “Test Method for Wind Load Resistance of Flashings Used with Metal Roof Systems,” has been developed by the Metal Construction Association to provide a method for testing metal roof flashings with the goal of improving the wind resistance of metal roof systems. When flashings fail, metal roof panels are exposed at the edges and ridges, and the roof system can peel. When a flashing system has been tested to resist design wind loads, it is less likely to fail, and the roof panels are more likely to stay secure.

Note: Documents in this section are provided as Adobe Acrobat PDF files. In order to print and view PDF files, the Adobe Acrobat Reader software/plugin, which runs on Microsoft Windows, Macintosh, OS/2 and various versions of UNIX, must be installed on your computer. Adobe Acrobat Reader is available for download as freeware from Adobe Acrobat's website. Please note that the resolution of on-screen versions is not as high as printed versions of PDF files.